Confirm the product and pipe-end mating geometry, receiving end and insertion depth against the supplied interface drawing before assembly. Confirm the product interface, pipe-end interface, sealing location and equipment flange standard in the supplied interface drawing. The two…

Also known as: Spigot Flange Adapter, Spigot-to-Flange Adaptor

BS-SJSG
Size Range φ63–φ800
Sealing Pressure ≥1.6MPa (232 PSI)
Body Material Q235 Carbon Steel / SS304 / SS316L / Duplex 2205
Coating Epoxy Powder
Request Quote

Usually replies within 24 hours sales@baoshuopipe.com

Socket Joint Series

Technical Specifications

Part Number BS-SJSG
Size Range φ63–φ800 · Custom sizes available beyond the above range
Body Material Q235 Carbon Steel / SS304 / SS316L / Duplex 2205
Seal Material EPDM
Sealing Pressure ≥1.6MPa (232 PSI)
Bolt Specification M16×80, Grade 8.8 High-Strength Bolts
Coating Epoxy Powder
Applicable Pipe Types UPVC, PVC-M
Working Conditions Standard Pressure

Custom Orders Available

This product can be customized to your specifications. Contact us with your requirements.

Request Custom Quote

Check the fit before ordering.

Measure the actual pipe
Nominal DN alone does not define the outside diameter. Confirm the pipe material, measured OD and condition.
Confirm the geometry
Provide dimensions of the connection or damaged area. Product shape, sealing length and end connections must match the job.
Match the seal to the service
Confirm medium, temperature and pressure together. A material name alone is not a service approval.
Plan a safe installation
Pipe integrity, isolation and installation procedure require a site-specific assessment. Suitability for live service must be confirmed.
Read the full technical guide7 chapters · complete product description

Product Overview

Confirm the product and pipe-end mating geometry, receiving end and insertion depth against the supplied interface drawing before assembly. Confirm the product interface, pipe-end interface, sealing location and equipment flange standard in the supplied interface drawing. The two adapters are chosen by which end of pipe you actually have in the trench.

Where it is installed

  • The product-side and pipe-side interface types require confirmation for the intended equipment connection.
  • Chamber and plant-room terminations
  • Record the actual pipe-end geometry in photographs and measurements for interface review.
  • Isolation points at the end of a push-fit run

Choosing the right size

Tell us the pipe outside diameter and material, which end you have in the trench, the flange standard and the line pressure — the two adapters are not interchangeable. Fitting: socket joint fittings installation manual; the socket-end version is the socket-to-flange adapter.

Where the seal actually sits on this part

The difference between this adapter and its socket-end twin is not cosmetic. Confirm the product-end and pipe-end geometry, receiving component and sealing location against the supplied interface drawing. Confirm the supplied sealing elements on both sides from the bill of materials and interface drawing. The engagement depth, lead-in geometry and seal arrangement require confirmation for the actual mating components.

That changes the load path. Confirm pressure-thrust transfer and the allowable equipment loads in the piping and connection design. Confirm pipe-side axial restraint and any anchor, tie or thrust-block requirements; a sealing ring alone is not evidence of thrust restraint. The two ends are not equivalent, and a layout that restrains one end has not restrained the other.

Incorrect lubrication or engagement can disturb a seal. Identify the receiving component and seal location from the supplied interface drawing, and inspect the assembled connection using the specified procedure.

Installation

  1. Identify which end the pipe actually presents in the trench before ordering. A bell end and a spigot end are not interchangeable, and this is the error that causes most returns.
  2. Identify the receiving component and supplied seal arrangement from the interface drawing, then inspect and clean them as specified.
  3. Measure and mark the engagement depth on the component identified in the supplied interface drawing.
  4. Apply only the lubricant and method specified for the supplied seal and mating components. Do not lubricate the flange face.
  5. Assemble the confirmed mating interfaces to the specified engagement and alignment using the supplied procedure; any tool or applied force requires that procedure.
  6. Fit a new flange gasket, bring the faces together by hand and tighten in a cross pattern in at least two stages.
  7. After flange assembly, verify the mating engagement against the supplied interface drawing. Confirm that flange assembly has not changed the specified engagement or imposed an unapproved load on the pipe-side connection.
  8. Support the pipe independently so its weight is not carried by the spigot shoulder, then test before backfill.

What to send with an enquiry

  • Pipe outside diameter and material, measured rather than nominal.
  • Which end the pipe presents, stated explicitly. Say whether the pipe in the trench is a bell or a spigot.
  • The dimensions of both mating interfaces, with the receiving component, seal arrangement and engagement depth identified from measurements and drawings.
  • The flange standard and drilling, named rather than assumed, with bolt count, bolt size, bolt circle and face type.
  • Pressure class, working pressure and surge pressure.
  • Medium and temperature.
  • The expected angular deflection and the proposed restraint arrangement at each confirmed interface.

Deflection is worth stating because the spigot shoulder is a stiff point in an otherwise flexible run. If the line will move there, say so and the layout can be adjusted before the part is made.

Failure modes, and where this adapter is the wrong part

The most expensive failure is ordering the wrong handedness. Both adapters look similar on a drawing and only one fits the pipe in the trench, so the trench condition belongs in the enquiry. The second is assembly without the specified lubrication or engagement checks, which can disturb the supplied seal arrangement. The third is using the adapter as an alignment tool: levering the flange into line loads the spigot shoulder, and that shoulder is where a crack will start.

Confirm the actual pipe-end geometry and supplied product interface before deciding whether this adapter can be used. Compare the confirmed interfaces and drawing when considering the socket-to-flange adapter. Do not use it where the line is expected to settle at the termination: the spigot shoulder is rigid and the movement will concentrate there. Where the ground is moving, a flexible coupling in the run absorbs the movement and the adapter stays a termination.

Where the defect is at the receiving socket rather than at the termination, the part to use is the mechanical joint split repair sleeve, which seals over the joint without disturbing it.

Materials and the standards behind them

The body is Q235 carbon steel to GB/T 700, epoxy coated to AWWA C210 / GB/T 18593, or SS304, SS316L or Duplex 2205 to ASTM A240 / GB/T 3280. Confirm the actual mating geometry and any concealed or crevice surfaces from the supplied drawing. Select the alloy and protective finish for the environment, and inspect any coating on mating surfaces as required by the supplied procedure.

Use SS316L where chlorides are present, and Duplex 2205 where high chloride and mechanical load come together. Confirm which component carries the sealing ring, its supplied compound and its material documentation against the actual medium and interface drawing. Flange fasteners are grade 8.8 to ISO 898-1 / GB/T 3098.1 on a carbon steel build, or SS304 bolts to ASTM A193 / GB/T 3098.6 on a stainless one. Fitting is covered in the socket joint fittings installation manual; quoting fields are on the spigot-to-flange adapter datasheet.

Documents

Related Products

Tee with Three Sockets

φ63–φ800

Socket-type tee fitting for branch connections on plain-end pipes. Three push-fit sockets with rubber ring seals —…

Cross with Four Sockets

φ63–φ800

Socket-type cross fitting for four-way intersections on plain-end pipes. Four push-fit sockets — used in complex piping…

Double-Socket Pipe Coupling

φ63–φ800

Straight socket coupling for joining two plain-end pipes of the same diameter. Bell-and-spigot style with rubber ring…

Need a different spec?

We customize size, material, seal, and coating to your requirements.